英语翻译4 技术要求4.1 选址原则4.1.1 危险废物焚烧厂的选址应符合当地的城乡规划和环境保护规划,并符合当地的大气

1个回答

  • 4 Technical Requirements

    4.1 siting principles

    4.1.1 siting hazardous waste incineration plants should comply with the local urban planning and environmental protection programs and comply with local air pollution control, water conservation, natural ecological protection requirements.

    4.1.2 shall be determined on the basis of environmental impact assessment of the conclusions of hazardous waste incineration plant site location and its distance from the surrounding population, and by the administrative department of environmental protection has the power to approve the ratification, and as a basis for planning control.

    4.1.3 When hazardous waste incineration plant site to conduct an environmental impact assessment should be a focus of harmful substances leaking hazardous waste incineration plant may produce various facilities, air pollutants (including odorous substances) production and diffusion as well as possible the risk of accidents and other factors, according to its environment ribbon category in the region, a comprehensive evaluation of its impact on the surrounding environment, the health of the population live, daily life and production activities, determine incinerators and permanent residents living spaces, agricultural land, surface water bodies and a reasonable relationship between the location of other sensitive objects

    4.2 incinerated requirements

    4.2.1 In addition to explosive and radioactive hazardous waste incineration can be carried outside.

    4.2.2 incineration of hazardous waste to deal with hazardous waste incineration needed to be compatible, so calorific value, the main organic component content of harmful organic chlorine content, heavy metal content, sulfur content, moisture and ash disposal facilities to meet the design incineration requirements, and as far as possible to ensure the stability of the waste into the furnace of physical and chemical properties.

    4.2.3 Incineration of medical waste should be collected according to the characteristics of various types of medical waste, control stability into the furnace of medical waste.

    Technical Requirements 4.3 incinerator facilities subject

    4.3.1 The main facilities include incineration of hazardous waste storage facilities, incinerators, and other incinerator exhaust.

    4.3.2 hazardous waste storage requirements

    4.3.2.1 Storage of hazardous waste should comply with GB 18597 standards.

    4.3.2.2 Construction of hazardous waste storage sites should consider incineration residues and incineration ash scratch.

    4.3.2.3 Protection hazardous waste storage sites and incineration facilities shall comply with fire safety requirements.

    4.3.3 Hazardous Waste Incinerator technical requirements

    4.3.3.1 hazardous waste incinerator technical performance indicators should meet the requirements of Table 1.

    Table 1 incinerator technical performance indicators

    4.3.3.2 hazardous waste incinerator during the operation to ensure that the system is in the vacuum state, to avoid harmful gases to escape.

    4.3.3.3 Hazardous waste incinerators must be equipped with exhaust gas purification systems, alarm systems and emergency equipment.

    4.3.4 hazardous waste incinerator exhaust requirements

    4.3.4.1 hazardous waste incinerator exhaust height should be determined according to the EIA.

    4.3.4.2 hazardous waste incineration facility if more exhaust sources, should focus to a multi-cylinder exhaust emissions or Assembling emissions.

    4.3.4.3 hazardous waste incinerator exhaust shall GB / T 16157 requirements, set up a permanent sampling holes, and install facilities for sampling and measurement.

    5 emission control requirements

    5.1 June 30, 2016, the existing hazardous waste incineration facilities, the concentration of pollutants in the flue gas emission limits specified in the implementation of GB18484-2001.

    5.2 Since July 1, 2016, the existing hazardous waste incineration facilities pollutant concentrations in flue gas emission limits specified in Table 2 execution.

    5.3 Since July 1, 2015, the new hazardous waste incineration facilities concentrations of pollutants in flue gas emissions execute the limits specified in Table 2.

    Table 2 hazardous waste incineration facility of pollutants in flue gas emissions limits