以下英文翻译是是否有错,谢谢.或者给些建议.

1个回答

  • The test fixtures have been adjusted as your below e-mail's request.

    Total 200pcs UUTs have been tested.In which,45pcs failed when the test ran to step 11.b as the attached test manual (on page 9).(测试架已经按照以下邮件要求调好,并且200被测机已经测试了,但是45部机在邮件测试文件中测试步骤11.b测试失败.)

    The voltage range of the 45pcs UUTs’were 15.4V-16.0V.But the request from test manual the voltage range should be 16-24V.(45部机的电压范围在15.4V-16.0V,测试文件要求是16-24V.)

    After checking,we did not find any problems on the PCBA or on any other echnological failure.(经检查,没有发现PCBA上元件损坏或进其它工艺问题.)

    Could you please advice further instructions?(请给一些建议如何进行一步.)